PURPOSE To visualize, quantitatively assess, and interpret outer retinal morphology by using high-speed, ultrahigh-resolution (UHR) OCT. METHODS Retinal imaging was performed in the ophthalmic clinic in a cross-section of 43 normal subjects with a 3.5-microm, axial-resolution, high-speed, UHR OCT prototype instrument, using a radial scan pattern (24(More)
We compared the performance of three OCT angiography (OCTA) methods: speckle variance, amplitude decorrelation and phase variance for imaging of the human retina and choroid. Two averaging methods, split spectrum and volume averaging, were compared to assess the quality of the OCTA vascular images. All data were acquired using a swept-source OCT system at(More)
PURPOSE To demonstrate ultrahigh-speed optical coherence tomography (OCT) imaging of the retina and optic nerve head at 249,000 axial scans per second and a wavelength of 1060 nm. To investigate methods for visualization of the retina, choroid, and optic nerve using high-density sampling enabled by improved imaging speed. METHODS A swept-source OCT(More)
PURPOSE To demonstrate two novel ophthalmic imaging techniques based on fast Spectral Optical Coherence Tomography (SOCT). DESIGN Prospective observation case report. METHODS SETTING Research laboratory. STUDY POPULATION A normal human subject. MAIN OUTCOME MEASURES Correlation of an optical coherence retinal tomogram with known retinal anatomy,(More)
We demonstrate ultrahigh speed spectral / Fourier domain optical coherence tomography (OCT) using an ultrahigh speed CMOS line scan camera at rates of 70,000 - 312,500 axial scans per second. Several design configurations are characterized to illustrate trade-offs between acquisition speed, resolution, imaging range, sensitivity and sensitivity roll-off(More)
PURPOSE The purpose of this study was to report normal macular thickness measurements and assess reproducibility of retinal thickness measurements acquired by a time-domain optical coherence tomography (OCT) (Stratus, Carl Zeiss Meditec, Inc., Dublin, CA) and three commercially available spectral/Fourier domain OCT instruments (Cirrus HD-OCT, Carl Zeiss(More)
High-speed, high-resolution optical coherence tomography (OCT) imaging of the human retina is demonstrated using a frequency-swept laser at 850 nm. A compact external cavity semiconductor laser design, optimized for swept-source ophthalmic OCT, is described. The laser enables an effective 16 kHz sweep rate with >10 mm coherence length and a tuning range of(More)
We describe a new ultrahigh speed Spectral OCT instrument making use of a CMOS camera and demonstrate high quality in vivo imaging of the anterior segment of the human eye. The high flexibility of the designed imaging system allows a wide range of imaging protocols. Two- and three-dimensional high quality OCT images of the cornea, the anterior chamber and(More)
Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal monitoring of CBF with high resolution in rats and mice. Using three-dimensional Doppler Optical Coherence Tomography and cranial window preparations, we present methods and(More)
AIMS To demonstrate ultrahigh-resolution, three-dimensional optical coherence tomography (3D-OCT) and projection OCT fundus imaging for enhanced visualisation of outer retinal pathology in non-exudative age-related macular degeneration (AMD). METHODS A high-speed, 3.5 mum resolution OCT prototype instrument was developed for the ophthalmic clinic.(More)