The use of Monte Carlo simulations in diagnostic medical imaging research is widespread due to its flexibility and ability to estimate quantities that are challenging to measure empirically. However, any new Monte Carlo simulation code needs to be validated before it can be used reliably. The type and degree of validation required depends on the goals of(More)
PURPOSE The proliferation of cone-beam CT (CBCT) has created interest in performance optimization, with x-ray scatter identified among the main limitations to image quality. CBCT often contends with elevated scatter, but the wide variety of imaging geometry in different CBCT configurations suggests that not all configurations are affected to the same(More)
Detector characterization with modulation transfer function (MTF) and detective quantum efficiency (DQE) inadequately predicts image quality when the imaging system includes focal spot unsharpness and patient scatter. The concepts of MTF, noise power spectrum, noise equivalent quanta and DQE were referenced to the object plane and generalized to include the(More)
Minimally invasive image-guided neuro-vascular interventions require very high image-resolution and quality, specifically over regions-of-interest (ROI) crucial to the procedure. ROI imaging or micro-angiography, allows limited patient integral radiation dose while permitting rapid frame transfer of high-resolution images. The design and performance of a(More)
We report on the variability in imaging system performance due to oblique x-ray incidence, and the associated transport of quanta (both x rays and optical photons) through the phosphor, in columnar indirect digital detectors. The analysis uses MANTIS, a combined x-ray, electron, and optical Monte Carlo transport code freely available. We describe the main(More)
We describe the anisotropy in imaging performance caused by oblique x-ray incidence in indirect detectors for breast tomosynthesis based on columnar scintillator screens. We use MANTIS, a freely available combined x-ray, electron, and optical Monte Carlo transport package which models the indirect detection processes in columnar screens, interaction by(More)
Cardiovascular disease in general and coronary artery disease (CAD) in particular, are the leading cause of death worldwide. They are principally diagnosed using either invasive percutaneous transluminal coronary angiograms or non-invasive computed tomography angiograms (CTA). Minimally invasive therapies for CAD such as angioplasty and stenting are(More)
The H operator represents the deterministic performance of any imaging system. For a linear, digital imaging system, this system operator can be written in terms of a matrix, H, that describes the deterministic response of the system to a set of point objects. A singular value decomposition of this matrix results in a set of orthogonal functions (singular(More)
We study the properties of a new microangiographic system, consisting of a Region of Interest (ROI) microangiographic detector, x-ray source, and patient. The study was performed under conditions intended for clinical procedures such as neurological diagnostic angiograms as well as treatments of intracranial aneurysms, and vessel-stenoses. The study was(More)