Previous claims that auditory stream segregation occurs in cochlear implant listeners are based on limited evidence. In experiment 1, eight listeners heard tones presented in a 30-s repeating ABA-sequence, with frequencies matching the centre frequencies of the implant's 22 electrodes. Tone A always stimulated electrode 11 (centre of the array); tone B(More)
The evidence that cochlear implant listeners routinely experience stream segregation is limited and equivocal. Streaming in these listeners was explored using tone sequences matched to the center frequencies of the implant's 22 electrodes. Experiment 1 measured temporal discrimination for short (ABA triplet) and longer (12 AB cycles) sequences (tone/silence(More)
The Birmingham bone-anchored hearing aid (BAHA) programme, since its inception in 1988, has fitted more than 300 patients with unilateral bone-anchored hearing aids. Recently, some of the patients who benefited extremely well with unilateral aids applied for bilateral amplification. To date, 15 patients have been fitted with bilateral BAHAs. The benefits of(More)
The Birmingham bone-anchored hearing aid (BAHA) programme has fitted more than 300 patients with unilateral bone-anchored hearing aids since 1988. Some of the patients who benefited well with unilateral aids and who had used bilateral conventional aids previously applied for bilateral amplification. To date, 15 patients have been fitted with bilateral(More)
One hundred consecutive adult cochlear implant patients, numbered 101 to 200 in an ongoing series, were prospectively monitored and data collected using the same protocol as for the first 100 patients. The study period was 1999 to 2001. The total number of procedures was 122. Changes in practice following the first 100 implants included a standard surgical(More)
CONCLUSION The Harmony processor was found to be reliable, comfortable and offered a substantially increased battery life compared with the previous generation processor. No significant improvement in speech understanding with HiRes was demonstrated from objective measures, but the majority of subjects showed a clear subjective preference for the(More)
A sudden increase in the amplitude of a component often causes its segregation from a complex tone, and shorter rise times enhance this effect. We explored whether this also occurs in implant listeners (n = 8). Condition 1 used a 3.5-s “complex tone” comprising concurrent stimulation on five electrodes distributed across the array of the Nucleus CI24(More)
OBJECTIVE To compare the fitting time requirements and the efficiency in achieving improvements in speech perception during the first 6 months after initial stimulation of computer-assisted fitting with the Fitting to Outcome eXpert' (FOX) and a standard clinical fitting procedure. METHOD Twenty-seven post-lingually deafened adults, newly implanted(More)
This study looks at the rates of explantation and reimplantation surgery in adult cochlear implant patients between 1990 and 2002 and also evaluates the surgical and audiological implications. 15 (5.5%) out of 272 adult cochlear implantees (288 cochlear implants: 282 Nucleus, 4 MED-EL Combi 40, 2 Clarion) needed their devices removed (explanted). 14 out of(More)