PURPOSE To compare the detectability between glaucomatous visual field changes using standard automated perimetry (SAP), frequency doubling technology (FDT), short-wavelength automated perimetry (SWAP), and flicker perimetry and structural changes using optical coherence tomography (OCT). PARTICIPANTS Fifty-nine eyes of fifty-nine patients with open-angle(More)
BackgroundTo quantify changes in metamorphopsia and retinal contraction in eyes with idiopathic epiretinal membrane (ERM) before and after a spontaneous separation of ERM.MethodsAmong 92 eyes of 92 patients with idiopathic ERM who were followed up at our hospital, 5 eyes of 5 patients had experienced a spontaneous separation of ERM during the follow-up(More)
PURPOSE To extrapolate the optimal test point resolution for assessment of glaucomatous visual field (VF) defects including subtle functional defects, we performed high-resolution perimetry with the 0.5 degrees test point resolution. SUBJECTS AND METHODS Subjects were 11 eyes of 11 normal volunteers and 16 eyes of 16 glaucomatous patients. Octopus 900(More)
PURPOSE We developed a new portable head-mounted perimeter, "imo", which performs visual field (VF) testing under flexible conditions without a dark room. Besides the monocular eye test, imo can present a test target randomly to either eye without occlusion (a binocular random single eye test). The performance of imo was evaluated. METHODS Using full HD(More)
PURPOSE A newly developed head-mounted perimeter termed "imo" enables visual field (VF) testing without a fixed head position. Because the positional relationship between the subject's head and the imo is fixed, the effects of head position changes on the test results are small compared with those obtained using a stationary perimeter. However, only ocular(More)
PURPOSE Test-retest variability (TRV) of visual field (VF) data seriously degrades our capacity to recognize true VF progression. We conducted repeated high-resolution perimetry with a test interval of 0.5° to investigate the sources of TRV. In particular, we examined whether the spatial variance of the observed sensitivity changes or if their absolute(More)
PURPOSE To assess the correlations between a patient's subjective perception of metamorphopsia and the clinical measurements of metamorphopsia by M-CHARTS and PreView PHP (PHP). METHODS The authors designed a 10-item questionnaire focusing on the symptoms of metamorphopsia and verified its validity with a Rasch analysis. M-CHARTS measured the minimum(More)
PURPOSE The purpose of this study is to evaluate the suitable visual field (VF) test conditions (target size, test type, and eccentricity) for the macular region, we investigated the correlations between the ganglion cell layer (GCL) thickness and 6 VF test results. METHODS We tested 32 eyes of patients (61.1±9.2 y) with preperimetric (6), early-stage(More)