Learn More
In functional MRI, it is often desirable to reduce the readout duration to make the acquired data less prone to T₂* susceptibility artifacts. In addition, a shorter readout length allows for a shorter minimum TE, which is important for optimizing SNR. This can be achieved by undersampling the k-space. However, the conventional Fourier transform-based(More)
This paper addresses the denoising problem associated with magnetic resonance spectroscopic imaging (MRSI), where signal-to-noise ratio (SNR) has been a critical problem. A new scheme is proposed, which exploits two low-rank structures that exist in MRSI data, one due to partial separability and the other due to linear predictability. Denoising is performed(More)
s t s t s t s t s t s t H s t s t s t s k t s k t s k t s k t s k t s k t C s k t s k t s k t (d) Denoised spatial distribution (b) Denoised spectrum (a) Noisy spectrum Figure 1. Denoising results with in-vivo experimental data: (a),(b) Spectrum from a particular voxel (shown in absolute mode); (c),(d) Spatial distribution from 1.6 ppm to 2 ppm.(More)
—Traditional classification algorithms, in many times, perform poorly on imbalanced data sets in which some classes are heavily outnumbered by the remaining classes. For this kind of data, minority class instances, which are usually much more of interest, are often misclassified. The paper proposes a method to deal with them by changing class distribution(More)
One of the key factors affecting functional MRI image reconstruction is field inhomogeneity. It is desirable to estimate both the distortion-free MRI image and field map simultaneously , thus compensating for image distortions caused by the field inhomogeneity. To solve this problem, which is called Joint Estimation problem, we propose a new non-iterative(More)
Magnetic resonance imaging (MRI) uses applied spatial variations in the magnetic field to encode spatial position. Therefore, nonuniformities in the main magnetic field can cause image distortions. In order to correct the image distortions, it is desirable to simultaneously acquire data with a field map in registration. We propose a joint estimation (JE)(More)
The choice of echo time (TE) is a complicated and controversial issue in proton MR spectroscopy, and represents a balancing act between signal-to-noise ratio and signal complexity. The TE values used in previous literature were selected either heuristically or based on limited empirical studies. In this work, we reconsider this problem from an estimation(More)
  • 1