A systematic method to optimize conditioning processes is introduced. By using the plasma monitoring tools such as self-excited electron resonance spectroscopy (SEERS) and optical emission spectroscopy (OES), chamber conditions are analyzed in real time and a conditioning process appropriate to each chamber condition is determined quickly. Through this real(More)