AIM The aim was to compare resuscitators' estimates of tidal volume (V(T)) and face mask leak with measured values during positive pressure ventilation (PPV) of newborn infants in the delivery room. PATIENTS AND METHODS The authors measured inflating pressures and V(T) delivered using a respiratory function monitor, and calculated face mask leak. After 60(More)
OBJECTIVE To investigate whether using a respiratory function monitor (RFM) during mask resuscitation of preterm infants reduces face mask leak and improves tidal volume (V(T)). STUDY DESIGN Infants receiving mask resuscitation were randomized to have the display of an RFM (airway pressure, flow, and V(T) waves) either visible or masked. RESULT(More)
INTRODUCTION Preterm infants with inadequate breathing receive positive pressure ventilation (PPV) by mask with variable success. The authors examined recordings of PPV given to preterm infants in the delivery room for prevalence of mask leak and airway obstruction. METHODS AND PATIENTS The authors reviewed recordings of infants at <32 weeks' gestation(More)
BACKGROUND Current neonatal resuscitation guidelines recommend using visual assessment of chest wall movements to guide the choice of inflating pressure during positive pressure ventilation (PPV) in the delivery room. The accuracy of this assessment has not been tested. We compared the assessment of chest rise made by observers standing at the infants' head(More)
BACKGROUND Current resuscitation guidelines recommend the use of simulation-based medical education (SBME) as an instructional methodology to improve patient safety and health. We sought to investigate the evidence-base for the effectiveness of SBME for neonatal and pediatric resuscitation training. METHOD Therefore, we conducted a systematic literature(More)
Laser acupuncture (LA) becomes more and more relevant in neonates and infants. With near-infrared spectroscopy (NIRS), a continuous and noninvasive measurement of tissue oxygenation is possible. Aim was to investigate, whether the application of LA was associated with any changes in regional cerebral oxygen saturation (rcSO2) in term and preterm neonates.(More)
Although recent advances in neonatal care have improved survival rates, rates of bronchopulmonary dysplasia remain unchanged. Although neonatologists are increasingly applying gentle ventilation strategies in the neonatal intensive care unit, the same emphasis has not been applied immediately after birth. A lung-protective strategy should start with the(More)
Objective:To assess development of fatigue during chest compressions (CCs) in simulated neonatal cardiopulmonary resuscitation (CPR).Study design:Prospective randomized manikin crossover study. Thirty neonatal healthcare professionals who successfully completed the Neonatal Resuscitation Program performed CPR using (i) 3:1 compression:ventilation (C:V)(More)
AIM Clinical assessment and end-tidal CO(2) (ETCO(2)) detectors are routinely used to verify endotracheal tube (ETT) placement. However, ETCO(2) detectors may mislead clinicians by failing to identify correct placement under a variety of conditions. A flow sensor measures gas flow in and out of an ETT. We reviewed video recordings of neonatal resuscitations(More)