• Publications
  • Influence
Endovascular Cooling Catheter for Selective Brain Hypothermia: An Animal Feasibility Study of Cooling Performance
BACKGROUND AND PURPOSE: Therapeutic hypothermia represents a promising neuroprotective treatment in acute ischemic stroke. Selective cerebral hypothermia applied early, prior to and duringExpand
  • 20
  • 1
  • PDF
Deploying CPU-Intensive Applications on MEC in NFV Systems: The Immersive Video Use Case
TLDR
This paper describes a novel MEC in an NFV system which successfully combines, at management level, MEC functional blocks with NFV Orchestrator, and can neutrally support any “over the top” Mobile Edge application with minimal integration effort. Expand
  • 11
  • 1
  • PDF
Combined Selective Cerebral Hypothermia and Mechanical Artery Recanalization in Acute Ischemic Stroke: In Vitro Study of Cooling Performance
BACKGROUND AND PURPOSE: Therapeutic hypothermia represents a promising neuroprotective treatment for patients with ischemic stroke. Selective, intracarotid blood cooling may initiate rapid and earlyExpand
  • 14
  • PDF
In Vitro Evaluation of Intra-Aneurysmal, Flow-Diverter-Induced Thrombus Formation: A Feasibility Study
BACKGROUND AND PURPOSE: Intracranial aneurysm treatment by flow diverters aims at triggering intra-aneurysmal thrombosis. By combining in vitro blood experiments with particle imaging velocimetryExpand
  • 19
  • PDF
Preclinical Evaluation of the Thrombogenicity and Endothelialization of Bare Metal and Surface-Coated Neurovascular Stents
BACKGROUND AND PURPOSE: Stent-assisted coiling is routinely used for the endovascular treatment of complex or wide-neck intracranial aneurysms. However, in-stent thrombosis, thromboembolic events,Expand
  • 19
  • PDF
Desktop MRI as a promising tool for mapping intra-aneurismal flow.
In this work we evaluate the performance of a 40-mm diameter bore 0.2T desktop Halbach tomograph to obtain 2D and 3D velocity maps for studying intra-aneurismal flow in the presence or absence ofExpand
  • 15
A Novel Plasma-Based Fluid for Particle Image Velocimetry (PIV): In-Vitro Feasibility Study of Flow Diverter Effects in Aneurysm Model
Particle image velocimetry (PIV) is a commonly used method for in vitro investigation of fluid dynamics in biomedical devices, such as flow diverters for intracranial aneurysm treatment. Since it isExpand
  • 4
In vitro investigation of chemical properties and biocompatibility of neurovascular braided implants
AbstractBraiding of Nitinol micro wires is an established technology for the manufacturing of fine-meshed neurovascular implants for tortuous vessel geometries. Electropolishing of wires before theExpand
  • 3
Dispositif médical ayant une structure de treillis et un système de traitement à l'aide d'une telle structure de treillis
L'invention concerne un dispositif medical comprenant une structure de treillis (10) de forme cylindrique, comprimable et expansible, qui comporte des segments peripheriques (20) de cellules fermeesExpand