• Publications
  • Influence
Femtosecond laser-assisted keyhole endokeratophakia: correction of hyperopia by implantation of an allogeneic lenticule obtained by SMILE from a myopic donor.
PURPOSE To describe endokeratophakia in which a small incision lenticule extraction (SMILE) lenticule from a myopic patient is implanted into a recipient eye through a small incision to correctExpand
LASIK for presbyopia correction in emmetropic patients using aspheric ablation profiles and a micro-monovision protocol with the Carl Zeiss Meditec MEL 80 and VisuMax.
PURPOSE To evaluate the monocular and binocular visual outcomes of LASIK with an aspheric micro-mono-vision protocol in emmetropic patients with presbyopia. METHODS A retrospective, noncomparativeExpand
Outcomes of small incision lenticule extraction (SMILE) in low myopia.
PURPOSE To report the visual and refractive outcomes of small incision lenticule extraction for low myopia using the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). METHODS AExpand
Optical Zone Centration Accuracy Using Corneal Fixation-based SMILE Compared to Eye Tracker-based Femtosecond Laser-assisted LASIK for Myopia.
PURPOSE To compare the optical zone centration accuracy between myopic eyes treated with small incision lenticule extraction (SMILE) and LASIK. METHODS Retrospective analysis of 100 consecutiveExpand
Reproducibility of manifest refraction between surgeons and optometrists in a clinical refractive surgery practice
Purpose To measure and compare the interobserver reproducibility of manifest refraction according to a standardized protocol for normal preoperative patients in a refractive surgery practice. SettingExpand
Outcomes of Re-treatment by LASIK After SMILE.
PURPOSE To report the outcomes of LASIK re-treatments after small incision lenticule extraction (SMILE). METHODS Retrospective review of all eyes to have undergone a re-treatment by LASIK afterExpand
LASIK for the Correction of High Hyperopic Astigmatism With Epithelial Thickness Monitoring.
PURPOSE To evaluate outcomes of high hyperopic LASIK using the MEL 80 excimer laser (Carl Zeiss Meditec, Jena, Germany). METHODS Retrospective analysis of 830 consecutive high hyperopic LASIKExpand
Effective and accurate screening for diabetic retinopathy using a 60 degree mydriatic fundus camera.
UNLABELLED OBJECTIVES. To establish whether an experienced endocrinologist could screen accurately for diabetic retinopathy using mydriatic 60 degree fundus photographs compared with a referenceExpand
Outcomes for Myopic LASIK With the MEL 90 excimer laser.
PURPOSE To evaluate the visual outcomes of myopic LASIK performed with the MEL 90 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) using the Triple-A profile with a 500-Hz pulse rate. METHODSExpand
Suction stability management in small incision lenticule extraction: incidence and outcomes of suction loss in 4000 consecutive procedures
To report the incidence and outcomes of suction loss during small incision lenticule extraction (SMILE).
...
1
2
3
4
5
...