Francisco Javier Pérez Lara

Learn More
A single colony of the non-native grass Poa pratensis L., which was introduced inadvertently to Cierva Point, Antarctic Peninsula, during the 1954–1955 season, was still present during a survey in February 2012, making it the longest surviving non-native vascular plant colony known in Antarctica. Since 1991, the grass cover has roughly tripled in size, with(More)
PURPOSE To investigate the relationship between accommodation and the optical aberrations of the whole human eye, as a function of age. METHODS Sixty healthy subjects with spherical ametropia in the range +/-3 D, astigmatism less than 1 D, corrected visual acuity of 20/18 or better, and normal findings in an ophthalmic examination were enrolled. Subjects(More)
A new analytical method based on capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) is proposed and validated for the identification and simultaneous quantification of eight quinolones for veterinary use in bovine raw milk. The studied quinolones include danofloxacin, sarafloxacin, ciprofloxacin, marbofloxacin, enrofloxacin, difloxacin,(More)
We present the validation of a developed method using capillary zone electrophoresis (CZE) for quantitative analysis of three phenoth-iazines: thiazinamium methylsulphate (TMS), promazine hydrochloride (PMH) and promethazine hydrochloride (PTH) in pharmaceutical formulations. The influence of various parameters affecting the CZE separation (buffer pH and(More)
Knowledge on the distribution and abundance of species is plagued by significant taxonomic and geographic biases that influence the analyses on biodiversity patterns. Due to this, standard, easy-to-use methods are needed to design efficient field campaigns that minimize data deficiencies. We evaluate the applicability, usefulness and effectiveness of a(More)
OBJECTIVE In the medical literature, thoracic disc protrusion has traditionally been considered a rare occurrence. We hypothesise that the incidence of such protrusions and their abdominal symptoms is higher than is generally believed and that their presence may account for a significant proportion of chronic non-visceral abdominal pains. Accordingly, the(More)
A CE instrument coupled with chemiluminescence (CL) detection was designed for the determination of promethazine hydrochloride (PTH) and promazine hydrochloride (PMH) in real samples. An important enhancement of the CL emission of luminol with potassium ferricyanide was observed in the presence of these phenothiazines; so this system was selected for their(More)
  • 1