PURPOSE To quantify the nature and composition of the light produced in optical fibers under different irradiation conditions and evaluate its impact on dosimetry. METHODS Irradiation of a bare PMMA optical fiber (Mitsubishi ESKA Premier) was performed using a superficial therapy unit, an Ir-192 HDR brachytherapy source, a Co-60 external-beam unit as well(More)
PURPOSE To perform dose profile and output factor measurements for the Exradin W1 plastic scintillation detector (PSD) for the Gamma Knife Perfexion (GKP) collimators in a Lucy phantom and to compare these values to an Exradin A16 ion chamber, EBT3 radiochromic film and treatment planning system (TPS) data. METHODS We used the Exradin W1 PSD which has a(More)
PURPOSE To study the effect of a strong magnetic field on the scintillation and the stem effect from a plastic scintillation detector (PSD) and evaluate its accuracy to measure dose. METHODS A plastic scintillation detector and a bare plastic fiber were placed inside a magnet of adjustable field strength (B=0-1.5T) and irradiated by a 6-MV photon beam(More)
PURPOSE The light generated in organic scintillators depends on both the radiation dose and the linear energy transfer (LET). The LET dependence leads to an under-response of the detector in the Bragg peak of proton beams. This phenomenon, called ionization quenching, must be corrected to obtain accurate dose measurements of proton beams. This work exploits(More)
PURPOSE To develop a new multi-point plastic scintillation detector (mPSD) that allows for simultaneous dose measurements at multiple points and uses a single optical guide. MATERIALS AND METHODS Two different prototypes were built. A two-point mPSD was built and light discrimination was based on the use of multiple color filters at the outputs of a(More)
PURPOSE To develop a novel multi-point plastic scintillation detector (mPSD) capable of accurately measuring dose at multiple positions simultaneously with the use of a single optical guide. METHODS We built a new generation of plastic scintillation detectors composed of multiple scintillating elements along a same optical transmission line. Three(More)
PURPOSE The purpose of this work is to characterize a 2-points mPSDs' optical chain using a spectral analysis to help selecting the optimal components for the detector. METHODS Twenty different 2-points mPSD combinations were built using 4 plastic scintillators (BCF10, BCF12, BCF60, BC430; St-Gobain) and quantum dots (QDs). The scintillator is said to be(More)
PURPOSE Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to(More)
PURPOSE To perform dose profile and output factor (OF) measurements with the Exradin W1 plastic scintillation detector (PSD) for small fields made by the high-definition multi-leaf collimator (MLC) on the TrueBeam STx system and to compare them to values measured with an IBA CC01 ionization chamber and a Sun Nuclear Edge detector diode for 6 MV photon(More)