Federico Zagni

  • Citations Per Year
Learn More
In order to extract quantitative parameters from PET images, several physical effects such as photon attenuation, scatter, and partial volume must be taken into account. The main objectives of this work were the evaluation of photon attenuation in small animals and the implementation of two attenuation correction methods based on X-rays CT and segmentation(More)
TH-MYCN transgenic mice represent a valuable preclinical model of neuroblastoma. Current methods to study tumor progression in these mice are inaccurate or invasive, limiting the potential of this murine model. The aim of our study was to assess the potential of small animal positron emission tomography (SA-PET) to study neuroblastoma progression in TH-MYCN(More)
Accurate determination of calibration factors for radionuclide activity meters is crucial for quantitative studies and in the optimization step of radiation protection, as these detectors are widespread in radiopharmacy and nuclear medicine facilities. In this work we developed the Monte Carlo model of a widely used activity meter, using the Geant4(More)
In this work we developed a Monte Carlo (MC) model of the Sedecal Argus pre-clinical PET scanner, using GATE (Geant4 Application for Tomographic Emission). This is a dual-ring scanner which features DOI compensation by means of two layers of detector crystals (LYSO and GSO). Geometry of detectors and sources, pulses readout and selection of coincidence(More)
In the planning of a new cyclotron facility, an accurate knowledge of the radiation field around the accelerator is fundamental for the design of shielding, the protection of workers, the general public and the environment. Monte Carlo simulations can be very useful in this process, and their use is constantly increasing. However, few data have been(More)
Radionuclide activity meters ("dose calibrators") are ionization chambers designed to measure relatively high amount of activities which are normally contained in radiopharmaceuticals. However, in the current radiopharmacy practice, these radiation detectors have been proposed to be used in measurements of samples with lower activity, such as in routine(More)
Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calculation of shielding and materials(More)