Fangjun Bao

Learn More
Purpose. To assess the consistency of anterior segment measurements obtained using a Sirius Scheimpflug/Placido photography-based topography system (CSO, Italy) and IOLMaster partial coherence interferometry (Carl Zeiss Meditec, Germany) in eyes with cataracts. Methods. A total of 90 eyes of 90 patients were included in this prospective study. The anterior(More)
PURPOSE To investigate the bilateral symmetry of the global corneal topography in normal corneas with a wide range of curvature, astigmatism and thickness values. DESIGN Cross-Sectional Study. METHODS Topography images were recorded for the anterior and posterior surfaces of 342 participants using a Pentacam. Elevation data were fitted to a general(More)
PURPOSE To evaluate repeatability and reproducibility of anterior corneal power measurements obtained with a new corneal topographer OphthaTOP (Hummel AG, Germany) and agreement with measurements by a rotating Scheimpflug camera (Pentacam HR, Oculus, Germany) and an automated keratometer (IOLMaster, Carl Zeiss Meditec, Germany). METHODS The right eyes of(More)
Optical coherence tomography (OCT) images can provide quantitative measurements of the eye's entire anterior segment. A new technique founded on a newly proposed level set-based shape prior segmentation model has been developed for automatic segmentation of the cornea's anterior and posterior boundaries. This technique comprises three major steps: removal(More)
PURPOSE To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract. METHODS Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III(More)
BACKGROUND Optical coherence tomography (OCT) is a non-invasive imaging system that can be used to obtain images of the anterior segment. Automatic segmentation of these images will enable them to be used to construct patient specific biomechanical models of the human eye. These models could be used to help with treatment planning and diagnosis of patients.(More)
PURPOSE To assess cataract surgery outcome using the Rasch scaled Chinese version of the Catquest short-form. METHODS The Chinese translated and culturally adapted version of the Catquest-9SF was interviewer-administered to patients, pre and post cataract surgery. Rasch analysis was performed on the baseline data to revise the Catquest. For the surgical(More)
Objective. To investigate mydriatic effect of intracamerally injected epinephrine hydrochloride during phacoemulsification and intraocular lens (IOL) implantation. Methods. Eighteen cataract patients for bilateral phacoemulsification were enrolled. To dilate pupil, one eye was randomly selected to receive intracamerally 1 mL epinephrine hydrochloride 0.001%(More)
BACKGROUD To evaluate the symmetry of corneal biomechanical metrics, measured using an ocular response analyzer (ORA) and self-built corneal inflation test platform, in bilateral rabbit corneas and to investigate their relationship with physical intraocular pressure (IOPp). METHODS Twenty fresh enucleated eyes from ten rabbits were used for ex vivo whole(More)
BACKGROUND The eye globe exhibits significant regional variation of mechanical behaviour. The aim of this present study is to develop a new experimental technique for testing intact eye globes in a form that is representative of in vivo conditions, and therefore suitable for determining the material properties of the complete outer ocular tunic. METHODS A(More)