Forces and moments delivered by PET-G aligners to an upper central incisor for labial and palatal translation
- F. Elkholy, T. Panchaphongsaphak, F. Kılıç, F. Schmidt, B. Lapatki
- MedicineJournal of Orofacial Orthopedics-fortschritte Der…
- 9 October 2015
PET-G aligners not featuring modifications are unsuitable for bodily movement of upper central incisors in labial or palatal directions and biomechanically evaluate the capability of bodily movement.
In-vitro results of rapid maxillary expansion on adults compared with finite element simulations.
- Andrew Boryor, A. Hohmann, F. Günter Sander
- MedicineJournal of Biomechanics
- 7 May 2010
Dimensional accuracy of jaw scans performed on alginate impressions or stone models
- A.B. Vogel, F. Kılıç, F. Schmidt, S. Rübel, B. Lapatki
- Computer Science, EngineeringJournal of Orofacial Orthopedics-fortschritte Der…
- 1 July 2015
Alginate impressions can be suitably digitized by structured-light scanning and offer considerably better dimensional accuracy than stone models, apparently, however, both impression scans and stone-model scans can offer adequate precision for orthodontic purposes.
Effectiveness of Combined Technique for the Correction of Prominent Ears
- C. Kemaloğlu, F. Kılıç, F. Doğan
- Medicine
- 29 July 2016
Amaç: Kepçe kulak deformitesi kulağın en sık konjenital deformitesidir. Deformiteye neden olan sebepler arasında başlıca silik antihelix, konkal fazlalık ve kulak lobülünün prominensi sayılabilir.…
Soft-tissue changes after maxillomandibular advancement surgery assessed with cone-beam computed tomography.
- Michael S Ryckman, S. Harrison, Ki Beom Kim
- MedicineAmerican Journal of Orthodontics and Dentofacial…
- 1 April 2010
Optical 3D scans for orthodontic diagnostics performed on full-arch impressions
- A.B. Vogel, F. Kılıç, F. Schmidt, S. Rübel, B. Lapatki
- Medicine, EngineeringJournal of Orofacial Orthopedics-fortschritte Der…
- 8 August 2015
The completeness of surface structure representation offered by full-arch impression scans in different situations of tooth (mal)alignment was evaluated and whether this completeness could be improved by performing rescans on the same impressions reduced sequentially to different levels of gingival height and by adding extra single scans to the number of single scans recommended by the manufacturer.
Novel Method for Superposing 3D Digital Models for Monitoring Orthodontic Tooth Movement
- F. Schmidt, F. Kılıç, N. E. Piro, M. Geiger, B. Lapatki
- MedicineAnnals of Biomedical Engineering
- 18 April 2018
Two novel numerical methods applicable to both maxilla and mandible are introduced and are particularly suitable for evaluation of pure treatment effects, because growth-related changes are ignored.
Generation of 3D digital models of the dental arches using optical scanning techniques
- D. Claus, J. Radeke, B. Lapatki
- Materials ScienceSeminars in orthodontics
- 1 December 2018
It is likely that in future intraoral scanning combined with 3D printing will completely replace conventional stone models of the dental arches.
Use of a modified expander during rapid maxillary expansion in adults: an in vitro and finite element study.
- Andrew Boryor, A. Hohmann, C. Sander
- Medicine, Materials ScienceThe International Journal of Oral and…
- 2013
The applied expansion force led to high tensile stress concentrations, mainly on the inter maxillary sutures, resulting in the opening of fused intermaxillary suture, thereby avoiding surgical intervention.
Reconstruction of a subtotally amputated auricle with a very narrow inferior pedicle
- C. Kemaloğlu, F. Kılıç, G. K. Günay
- Medicine, EngineeringCase Reports in Plastic Surgery and Hand Surgery
- 11 November 2015
The left ear of a 57-year-old male patient was subtotally amputated due to an iron-plate cutting accident and only a 5-mm inferior skin pedicle connected the amputated ear to the lobule.
...
...