We present a procedure that compensates for phase aberrations in digital holographic microscopy by computing a polynomial phase mask directly from the hologram. The phase-mask parameters are computed automatically without knowledge of physical values such as wave vectors, focal lengths, or distances. This method enables one to reconstruct correct and(More)
The concept of numerical parametric lenses (NPL) is introduced to achieve wavefront reconstruction in digital holography. It is shown that operations usually performed by optical components and described in ray geometrical optics, such as image shifting, magnification, and especially complete aberration compensation (phase aberrations and image distortion),(More)
Introducing a microscope objective in an interferometric setup induces a phase curvature on the resulting wavefront. In digital holography, the compensation of this curvature is often done by introducing an identical curvature in the reference arm and the hologram is then processed using a plane wave in the reconstruction. This physical compensation can be(More)
We present first results on a method enabling mechanical scanning-free tomography with submicrometer axial resolution by multiple-wavelength digital holographic microscopy. By sequentially acquiring reflection holograms and summing 20 wavefronts equally spaced in spatial frequency in the 485-670 nm range, we are able to achieve a slice-by-slice tomographic(More)
We demonstrate the use of digital holographic microscopy (DHM) as a metrological tool in micro-optics testing. Measurement principles are compared with those performed with Twyman-Green, Mach-Zehnder, and white-light interferometers. Measurements performed on refractive microlenses with reflection DHM are compared with measurements performed with standard(More)
For what we believe to be the first time, digital holographic microscopy is applied to perform optical diffraction tomography of a pollen grain. Transmission phase images with nanometric axial accuracy are numerically reconstructed from holograms acquired for different orientations of the rotating sample; then the three-dimensional refractive index spatial(More)
In digital holographic microscopy, shot noise is an intrinsic part of the recording process with the digital camera. We present a study based on simulations and real measurements describing the shot-noise influence in the quality of the reconstructed phase images. Different configurations of the reference wave and the object wave intensities will be(More)
A technique to perform two-wavelengths digital holographic microscopy (DHM) measurements with a single hologram acquisition is presented. The vertical measurement range without phase ambiguity is extended to the micron-range, thanks to the resulting synthetic wavelength defined by the beating of two wavelengths with a separation of about 80nm. Real-time(More)
We present a method for submicrometer tomographic imaging using multiple wavelengths in digital holographic microscopy. This method is based on the recording, at different wavelengths equally separated in the k domain, in off-axis geometry, of the interference between a reference wave and an object wave reflected by a microscopic specimen and magnified by a(More)
Digital holographic microscopy (DHM) is an interferometric technique that allows real-time imaging of the entire complex optical wavefront (amplitude and phase) reflected by or transmitted through a sample. To our knowledge, only the quantitative phase is exploited to measure topography, assuming homogeneous material sample and a single reflection on the(More)