PURPOSE We develop a realistic and flexible 4-D digital mouse phantom and investigate its usefulness in molecular imaging research. METHODS Organ shapes were modeled with non-uniform rational B-spline (NURBS) surfaces based on high-resolution 3-D magnetic resonance microscopy (MRM) data. Cardiac and respiratory motions were modeled based on gated magnetic(More)
Effects of different scatter compensation methods incorporated in fully 3D iterative reconstruction are investigated. The methods are: (i) the inclusion of an 'ideal scatter estimate' (ISE); (ii) like (i) but with a noiseless scatter estimate (ISE-NF); (iii) incorporation of scatter in the point spread function during iterative reconstruction ('ideal(More)
Partial volume (PV) effects degrade the quantitative accuracy of SPECT brain images. In this paper, we extended a PV compensation (PVC) method originally developed for brain PET, the geometric transfer matrix (GTM) method, to brain SPECT using iterative reconstruction-based compensations. In the GTM method a linear transform between the true regional(More)
Receiver operating characteristic (ROC) analysis is well established in the evaluation of systems involving binary classification tasks. However, medical tests often require distinguishing among more than two diagnostic alternatives. The goal of this work was to develop an ROC analysis method for three-class classification tasks. Based on decision theory,(More)
In this paper, we apply the channelized Hotelling observer (CHO) using a defect detection task to the optimization and evaluation of three-dimensional iterative reconstruction-based compensation methods for myocardial perfusion single-photon emission computed tomography (SPECT). We used a population of 24 mathematical cardiac-torso phantoms that(More)
Previously, we have developed a decision model for three-class receiver operating characteristic (ROC) analysis based on decision theory. The proposed decision model maximizes the expected decision utility under the assumption that incorrect decisions have equal utilities under the same hypothesis (equal error utility assumption). This assumption reduced(More)
Previously, we have proposed a method for three-class receiver operating characteristic (ROC) analysis based on decision theory. In this method, the volume under a three-class ROC surface (VUS) serves as a figure-of-merit (FOM) and measures three-class task performance. The proposed three-class ROC analysis method was demonstrated to be optimal under(More)
UNLABELLED Attenuation, photon scatter, and distance-dependent collimator-detector response are major degrading factors in myocardial SPECT images. The current study investigated whether compensation for these factors improves perfusion defect detectability, and compared the results for human observers with a previous study using a mathematical observer. (More)
Accurate and precise estimation of organ activities is essential for treatment planning in targeted radionuclide therapy. We have previously evaluated the impact of processing methodology, statistical noise and variability in activity distribution and anatomy on the accuracy and precision of organ activity estimates obtained with quantitative SPECT (QSPECT)(More)