Ellery Harrington

Learn More
Time-averaged holograms describing the sound-induced motion of the tympanic membrane (TM) in cadaveric preparations from three mammalian species and one live ear were measured using opto-electronic holography. This technique allows rapid measurements of the magnitude of motion of the tympanic membrane surface at frequencies as high as 25 kHz. The holograms(More)
Sound-induced motion of the surface of the human tympanic membrane (TM) was studied by stroboscopic holographic interferometery, which measures the amplitude and phase of the displacement at each of about 40,000 points on the surface of the TM. Measurements were made with tonal stimuli of 0.5, 1, 4 and 8 kHz. The magnitude and phase of the sinusoidal(More)
UNLABELLED Opto-electronic computer holographic measurements were made of the tympanic membrane (TM) in cadaveric chinchillas. Measurements with two laser wavelengths were used to compute the 3D-shape of the TM. Single laser wavelength measurements locked to eight distinct phases of a tonal stimulus were used to determine the magnitude and the relative(More)
HYPOTHESIS The sound-induced motion of the tympanic membrane has features that are most consistent with modal responses to a uniform stimulus. BACKGROUND Conceptual models of the coupling of tympanic membrane motion to the ossicular chain can be classified as either modal responses to a uniform stimulation of the entire membrane or traveling wave models(More)
  • 1