Dong-Hwan Jun

Learn More
BACKGROUND Coronary angiography (CAG) is an invasive diagnostic procedure, which could lead to procedure related complications. One of the well known post-procedural complications is cerebral embolic infarction with or without symptoms. Silent embolic cerebral infarction (SECI) has clinical significance because it can progress to a decline in cognitive(More)
BACKGROUND The ratio of peak early diastolic mitral inflow to annular velocity (E/E') and left atrial size could provide prognosis on congestive heart failure (CHF). N-terminal Pro B-type natriuretic peptide (NT-ProBNP) has also been useful for predicting adverse cardiac events. However, it is not clear how these parameters compare with conventional risk(More)
We demonstrated the efficiency improvement of GaAs single-junction (SJ) solar cells with the single-material zinc sulfide (ZnS) bi-layer based on the porous/dense film structure, which was fabricated by the glancing angle deposition (GLAD) method, as an antireflection (AR) coating layer. The porous ZnS film with a low refractive index was formed at a high(More)
A 79-year-old man was followed in our hospital for 4 years following primary percutaneous coronary intervention at another hospital to deploy two stents at the left anterior descending coronary artery for acute myocardial infarction (AMI). At the first visit in our hospital, echocardiography revealed a small ventricular septal defect (VSD, 0.8 to 1.0 cm) in(More)
Recently, the number of patients in whom a drug-eluting stent (DES) has recently been implanted and who need to undergo surgery or the most invasive procedure is increasing. However, there are limited data about the risk of perioperative thrombosis of DES. We evaluated the incidence and the risk factors of DES thrombosis during the perioperative period.(More)
We report a case of infective endocarditis of the mitral valve, which was accompanied by pulmonary emboli traveling through an atrial septal defect. An 18-year-old male was admitted to our hospital due to a fever, polyarthritis and subcutaneous hemorrhage. Transthoracic echocardiography revealed a mobile mass and possible vegetation lodged in the mitral(More)
We report the efficiency enhancement of III-V InGaP/GaAs/ Ge triple-junction (TJ) solar cells using a novel structure, i.e., vertically-oriented gallium oxide hydroxide (GaOOH) nanopillars (NPs), as an antireflection coating. The optical reflectance properties of rhombus-shaped GaOOH NPs, which were synthesized by a simple, low-cost, and large-scalable(More)
GaAs solar cells with nanostructured emitter layers were fabricated via metal-assisted chemical etching. Au nanoparticles produced via thermal treatment of Au thin films were used as etch catalysts to texture an emitter surface with nanohole structures. Epi-wafers with emitter layers 0.5, 1.0, and 1.5 um in thickness were directly textured and a window(More)
In this study, we report experimental results on the epitaxial growth of InP layer on GaAs (001) substrate by using MOCVD. We have systematically controlled nucleation steps in order to obtain InP epitaxial layers with high crystallinity quality. The controlling parameters were flow ratio of V/IIIsources and thicknesses of nucleation layer for nucleation(More)
In this paper, we describe a design, simulation, and fabrication of an InGaAs/InP single photon avalanche photodiode (SPAD), which requires a much higher gain, compared to APD's for conventional optical communications. To achieve a higher gain, an efficient multiplication width control is essential because it significantly affects the overall performance(More)
  • 1