Purpose – This paper aims to describe computer-aided design and rapid prototyping (RP) systems for the preoperative planning and fabrication of custom-made implant. Design/methodology/approach – A patient with mandible defect underwent reconstruction using custom-made implant. 3D models of the patient's skull are generated based on computed tomography image(More)
Increasing evidences show that subchondral bone may play a significant role in the repair or progression of cartilage damage in situ. However, the exact change of subchondral bone during osteochondral repair is still poorly understood. In this paper, biphasic osteochondral composite scaffolds were fabricated by 3D printing technology using PEG hydrogel and(More)
The reconstruction of maxillofacial bone defects by the intraoperative modeling of implants may reduce the predictability of the esthetic result, leading to more invasive surgery and increased surgical time. To improve the maxillofacial surgery outcome, modern manufacturing methods such as rapid prototyping (RP) technology and methods based on reverse(More)
Exploration of transient Granger causal interactions in neural sources of electrophysiological activities provides deeper insights into brain information processing mechanisms. However, the underlying neural patterns are confounded by time-dependent dynamics, non-stationarity and observational noise contamination. Here we investigate transient Granger(More)
Lower extremity musculoskeletal computational models play an important role in predicting joint forces and muscle activation simultaneously and are valuable for investigating functional outcomes of the implants. However, current computational musculoskeletal models of total knee replacement rarely consider the bearing surface geometry of the implant.(More)
Mal-rotation of the components in total knee arthorplasty (TKA) is a major cause of postoperative complications, with an increased propensity for implant loosening or wear leading to revision. A musculoskeletal multi-body dynamics model was used to perform a parametric study of the effects of the rotational mal-alignments in TKA on the knee loading under a(More)
BACKGROUND There is a lack of understanding of the morphological characteristics of the cartilage-bone interface. Materials that are currently being used in tissue engineering do not adequately support the regeneration of bone and cartilage tissues. The present study aimed to explore the morphological characteristics of cartilage-bone transitional(More)
Musculoskeletal lower limb models are widely used to predict the resultant contact force in the hip joint as a non-invasive alternative to instrumented implants. Previous musculoskeletal models based on rigid body assumptions treated the hip joint as an ideal sphere with only three rotational degrees of freedom. An musculoskeletal model that considered(More)
BACKGROUND The purpose of this study was to investigate the effect of latency on the development of bone lengthening force and bone mineralization during mandible distraction osteogenesis. METHODS Distraction tensions were investigated at different latency period in 36 rabbits using internal unilateral distractor. Strain gauges were prepared and attached(More)
We introduce a new type of parallel redundant action attitude adjustment mechanism which has six degrees of freedom that can be used for the automatic assembly of large parts. Take four spherical pairs as the supporting points, the spherical pairs' ball-end will self-adaptive rotate around an axis while the motors make the spherical pairs linear motion. Set(More)