OBJECTIVE The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use. MATERIALS AND METHODS Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT(More)
PURPOSE The study was aimed to provide objective evidence about the mammographic image quality in Croatia, to compare it between different types of MG facilities and to identify the most common deficiencies and possible reasons as well as the steps needed to improve image quality. MATERIALS AND METHODS A total of 420 mammographic examinations collected(More)
The purpose of this study is to investigate the need for and the possible achievements of a comprehensive QA programme and to look at effects of simple corrective actions on image quality in Croatia and in Serbia. The paper focuses on activities related to the technical and radiological aspects of QA. The methodology consisted of two phases. The aim of the(More)
PURPOSE The objective is to study mammography practice from an optimisation point of view by assessing the impact of simple and immediately implementable corrective actions on image quality. MATERIALS AND METHODS This prospective multinational study included 54 mammography units in 17 countries. More than 21,000 mammography images were evaluated using a(More)
OBJECTIVE The purpose of our study was to investigate the level of radiation protection of patients and staff during interventional procedures in 20 countries of Africa, Asia, and Europe. SUBJECTS AND METHODS In a multinational prospective study, information on radiation protection tools, peak skin dose (PSD), and kerma-area product (KAP) was provided by(More)
The interventional cardiology was recently implemented at the University Hospital of Osijek. Patients' absorbed doses during coronary angiography (CA) and the percutaneous transluminal coronary angioplasty (PTCA) procedures were measured and compared with published data and international standards. All patients undergoing CA or PTCA procedures during a(More)
Lung-cancer risk to the general population from indoor radon remains controversial, although studies of radon exposure have established that radon decay products have been a cause of lung cancer among miners. For the case group of patients, suffering from lung cancer, and the control group distributions of the number of homes with high indoor levels of(More)
From the prescription to the delivery of a radiotherapy treatment, a team of professionals from a number of disciplines is involved. In this way significant potential for errors leading to an accidental exposure becomes apparent. Comprehensive quality assurance/quality control (QA/QC) program to minimize such errors is, therefore, required. One aspect of(More)
Radiation environment is a complex mixture of charged particles of the solar and galactic origin, as well as of secondary particles created in an interaction of galactic cosmic particles with the nuclei of the Earth's atmosphere. A radiation field at aircraft altitude consists of different types of particles, mainly photons, electrons, positrons and(More)
INTRODUCTION External photon beam modulation using compensators in order to achieve a desired dose distribution when brachytherapy treatment is followed by external beam radiation is a well-established technique. A compensator modulates the central part of the beam, and the dose beneath the thickest part of the compensator is delivered mostly by scattered,(More)