Visual evoked potentials (VEPs) can provide important diagnostic information regarding the functional integrity of the visual system. This document updates the ISCEV standard for clinical VEP testing and supersedes the 2004 standard. The major change in this revision is that test parameters have been made more precise to achieve better consistency of(More)
Pattern visual evoked potentials (P-VEPs) were recorded in 161 human infants who were between 3 weeks and 2 yr of age. The latency of the first reproducible positive peak in the P-VEP was measured monocularly and binocularly for five sizes of phase alterations checkerboard stimuli (range: 120' to 7.5' check widths). Rapid visual maturation in the first 6(More)
This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV), presents an updated and revised ISCEV Standard for full-field clinical electroretinography (ffERG or simply ERG). The parameters for Standard flash stimuli have been revised to accommodate a variety of light sources including gas discharge lamps and light(More)
The clinical multifocal electroretinogram (mfERG) is an electrophysiological test of local retinal function. With this technique, many local ERG responses are recorded quasi-simultaneously from the cone-driven retina under light-adapted conditions. This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV: www.iscev.org(More)
Visual evoked potentials (VEPs) can provide important diagnostic information regarding the functional integrity of the visual system. This document updates the ISCEV standard for clinical VEP testing and supersedes the 2009 standard. The main changes in this revision are the acknowledgment that pattern stimuli can be produced using a variety of technologies(More)
The luminance-response function of the brief flash full-field photopic electroretinogram (ERG) rises to a peak before falling to a sub-maximal plateau -- the 'photopic hill'. The combination of on- and off-responses inherent in the brief flash photopic ERG suggests that this luminance-response function could be modelled by the sum of a Gaussian function and(More)
The pattern electroretinogram (PERG) is a retinal response evoked by a contrast-reversing pattern, usually a black and white checkerboard, which provides information about macular and retinal ganglion cell function. This document from the International Society for Clinical Electrophysiology of Vision ( www.iscev.org ) is a scheduled revision of the ISCEV(More)
The clinical electro-oculogram (EOG) is an electrophysiological test of function of the outer retina and retinal pigment epithelium (RPE) in which changes in electrical potential across the RPE are recorded during successive periods of dark and light adaptation. This document presents the 2010 EOG Standard from the International Society for Clinical(More)
PURPOSE Results in several studies have suggested that the visual evoked potential (VEP) amplitude can vary with stimulus duration. The purpose of this study was to determine whether acuity estimates obtained by extrapolation of the sweep VEP are altered by this adaptation effect. METHODS Sweep VEP data were obtained from 16 healthy observers under(More)
Visual evoked potential (VEP) studies are of great value in a wide variety of pediatric patients, including those with disorders of the sensory visual pathway and those at risk for visual pathway damage. VEPs are simple, non-invasive, and are particularly appropriate for infants and young children who cannot communicate visual symptoms or cooperate for(More)