Learn More
The relations between two tooth indices, post-canine area and incisor width in the upper jaw, and three variables, diet, body weight and body weight dimorphism, were examined separately for the males and females of 29 cercopithecoid species. Each species was assigned to one of three diet classes (folivore, frugivore, omnivore). Data on the other variable(More)
Two landuse grids were available for these catchments; one in 1995 was derived from satellite imagery and contained a relatively undifferentiated landuse classification (lumping all forest types into one category); the other in 2003 was derived from a mix of satellite imagery, ground truthing, and mapping, and better differentiated between landuse types(More)
It has been demonstrated with an in vitro model that hemoperfusion through Amberlite XAD 4 or coated charcoal containing cartridges eliminates carbromal and its ureid derivatives more efficiently than hemodialysis. The following clearances were measured in vitro (blood flow: 200 ml/min): Coil dialyser (1 m2): 55–85 ml/min, charcoal hemoperfusion: 100–125(More)
Real-time methods for differentiation of in-plane displacement fields produced by the moire interferometry technique are introduced. Two approaches are developed: (1) optical shearing of displacement patterns and (2) superposition of two lateral shear interferograms of wavefronts from 2 diffraction orders of the specimen grating. Coherence problems are(More)
While high-sensitivity moiré interferometry requires monochromatic light, an auxiliary compensator grating removes the requirement. Experimental verification utilized white light for moiré interference of sensitivity 0.833 microm/fringe. Configurations readily amenable to compensation include moiré fringe multiplication by even factors and the(More)
A high-frequency phase grating on a specimen surface is illuminated symmetrically by two oblique beams. The diffracted beams emerge with wave front warpages that define both the in-plane U and out-of-plane W displacement fields. Contour maps of these wave fronts, with added carrier fringes, are obtained as a single photographic record. They are manipulated(More)
The materials mentioned above are reextracted from an ether solution by 2 N sodium hydroxide. The UV extinction of the aqueous layer at 232 nm and 30° C is followed by means of a slave recorder. The original extinction is found by back-extrapolating to the time of re-extraction. It has to be corrected for the “biological matrix” by subtracting the(More)
The materials mentioned above are reextracted from an ether solution by 2 N sodium hydroxide. The UV extinction of the aqueous layer at 232 nm and 30 degrees C is followed by means of a slave recorder. The original extinction is found by back-extrapolating to the time of re-extraction. It has to be corrected for the "biological matrix" by subtracting the(More)