Christian Steiding

Learn More
PURPOSE To investigate the dose saving potential of direct-converting CdTe photon-counting detector technology for dedicated breast CT. MATERIALS AND METHODS We analyzed the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of two detector technologies, suitable for breast CT (BCT): a flat-panel(More)
PURPOSE Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient(More)
X-ray computed tomography (CT) has been proposed and evaluated multiple times as a potentially alternative method for breast imaging. All efforts shown so far have been criticized and partly disapproved because of their limited spatial resolution and higher patient dose when compared to mammography. Our concept for a dedicated breast CT (BCT) scanner(More)
RATIONALE AND OBJECTIVES This study compared a novel photon-counting breast computed tomography (pcBCT) system with digital mammography (DM) and digital breast tomosynthesis (DBT) systems. For this reason, surgical specimens were examined with all three techniques and rated by three observers. MATERIALS AND METHODS A total of 30 surgical specimens were(More)
PURPOSE Modern computed tomography (CT) systems are supporting increasingly fast rotation speeds, which are a prerequisite for fast dynamic acquisition, e.g. in perfusion imaging, and for new modalities such as dedicated breast CT, where breathhold scanning is indicated. However, not all detector technologies are supporting the high frame rates that are(More)
OBJECTIVES The performance of metal artifact reduction (MAR) methods in x-ray computed tomography (CT) suffers from incorrect identification of metallic implants in the artifact-affected volumetric images. The aim of this study was to investigate potential improvements of state-of-the-art MAR methods by using prior information on geometry and material of(More)
PURPOSE The aim of this work was to implement, validate, and compare two procedures for routine image quality (IQ) assurance in dental cone-beam computed tomography (CBCT): 1. the German standard DIN 6868 - 161 introduced in 2013 and 2. the established standard IEC 61,223 - 3-5 for clinical CT x-ray equipment referenced as "DIN" and "IEC" below. MATERIALS(More)
The purpose of this study was to validate the use of a single shaped filter (SF) for computed tomography (CT) using variable source-to-filter distance (SFD) for the examination of different object diameters.A SF was designed by performing simulations with the purpose of achieving noise homogeneity in the reconstructed volume and dose reduction for arbitrary(More)