Catharina Lange

Learn More
OBJECTIVE Dopamine transporter single-photon emission computed tomography (SPECT) with I-FP-CIT is used widely in the diagnosis of clinically uncertain parkinsonian syndromes. In terms of the evaluation of FP-CIT SPECT, some practice guidelines state that visual interpretation alone is generally sufficient in clinical patient care, whereas other guidelines(More)
BACKGROUND Positron emission tomography (PET) with the glucose analog F-18-fluorodeoxyglucose (FDG) is widely used in the diagnosis of neurodegenerative diseases. Guidelines recommend voxel-based statistical testing to support visual evaluation of the PET images. However, the performance of voxel-based testing strongly depends on each single preprocessing(More)
PURPOSE Attenuation correction (AC) based on low-dose computed tomography (CT) could be more accurate in brain single-photon emission computed tomography (SPECT) than the widely used Chang method, and, therefore, has the potential to improve both semi-quantitative analysis and visual image interpretation. The present study evaluated CT-based AC for dopamine(More)
UNLABELLED Semi-quantitative characterization of dopamine transporter availability from single photon emission computed tomography (SPECT) with 123I-ioflupane (FP-CIT) is based on uptake ratios relative to a reference region. The aim of this study was to evaluate the whole brain as reference region for semi-quantitative analysis of FP-CIT SPECT. The(More)
Quantitative estimates of dopamine transporter availability, determined with [123I]FP-CIT SPECT, depend on the SPECT equipment, including both hardware and (reconstruction) software, which limits their use in multicentre research and clinical routine. This study tested a dedicated reconstruction algorithm for its ability to reduce camera-specific(More)
MRI-based hippocampus volume, a core feasible biomarker of Alzheimer's disease (AD), is not yet widely used in clinical patient care, partly due to lack of validation of software tools for hippocampal volumetry that are compatible with routine workflow. Here, we evaluate fully-automated and computationally efficient hippocampal volumetry with FSL-FIRST for(More)
Step-and-shoot mode with many angular steps results in long frame duration limiting the capability of single-photon emission computed tomography (SPECT) for fast dynamic scans. The present study evaluates acquisition with reduced angular sampling for fast imaging in preclinical research with the nanoSPECT/CTplus four-head multi-pinhole system. Measurements(More)
Positron emission tomography (PET) allows detecting molecular brain changes in vivo. However, the accuracy of PET is limited by partial volume effects (PVE) that affects quantitative analysis and visual interpretation of the images. Although PVE-correction methods have been shown to effectively increase the correspondence of the measured signal with the(More)
Loss of brain tissue becomes notable to cerebral magnetic resonance imaging (MRI) at age 30 years, and progresses more rapidly from mid 60s. The incidence of dementia increases exponentially with age, and is all too frequent in the oldest old (≥ 90 years of age), the fastest growing age group in many countries. However, brain pathology and cognitive decline(More)
Brain MRI white matter hyperintensities (WMHs) are common in elderly subjects. Their impact on cognition, however, appears highly variable. Complementing conventional scoring of WMH load (volume and location) by quantitative characterization of the shape irregularity of WMHs might improve the understanding of the relationship between WMH load and cognitive(More)