Carlos Dorronsoro

Learn More
This study investigated differences in geometrical properties and optical aberrations between a group of hyperopes and myopes (age-matched 30.3+/-5.2 and 30.5+/-3.8 years old, respectively, and with similar absolute refractive error 3.0+/-2.0 and -3.3+/-2.0, respectively). Axial length (AL) was measured by means of optical biometry, and corneal apical(More)
The monochromatic aberrations of the human eye along the temporal meridian are studied by a novel laser ray-tracing method. It consists of delivering a narrow laser pencil into the eye through a given point on the pupil and recording the aerial image of the retinal spot with a CCD camera. The relative displacement of this image is proportional to the(More)
We evaluated the accommodative response to a stimulus moving from 0 to 6 D following a staircase function under natural, corrected, and induced optical aberrations, using an adaptive-optics (AO) electromagnetic deformable mirror. The accommodative response of the eye (through the mirror) and the change of aberrations were measured on 5 subjects using a(More)
A new technique is presented for the non-invasive imaging of the dynamic response of the cornea to an air puff inducing a deformation. A spectral OCT instrument combined with an air tonometer in a non-collinear configuration was used to image the corneal deformation over full corneal cross-sections, as well as to obtain high speed measurements of the(More)
PURPOSE To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL). METHODS EIGHTEEN EYES PARTICIPATED IN THIS STUDY: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine(More)
We present an efficient linear minimum mean square error (LMMSE) method for reconstructing full color images from single sensor color filter array (CFA) data. We use a representative set of full color images to estimate the joint spatial-chromatic covariance among pixel color components. Then, we derive from it a set of joint color-space, small linear(More)
PURPOSE To evaluate the objective accommodative response, change of aberrations, and depth of focus in eyes implanted with the Crystalens accommodative intraocular lens (IOL) at different accommodative demands. DESIGN Prospective, observational study. METHODS Eleven cataract patients (22 eyes) who underwent implantation of a Crystalens accommodative(More)
METHODS. The instrument provides the eye with two superimposed images, aligned and with the same magnification, but with different defocus states. Subjects looking through the instrument are able to experience pure simultaneous vision, with adjustable refractive correction and addition power. The instrument is used to investigate the impact of the amount of(More)
PURPOSE Our aim was to obtain a complete description of the interactions of rigid gas permeable (RGP) contact lenses with the optics of normal eyes. METHODS We measured total and anterior-surface aberrations in four subjects, who were all long-term RGP contact lens wearers. The anterior-surface wave aberration was obtained from videokeratographic(More)
We evaluated the visual benefit of correcting astigmatism and high-order aberrations with adaptive optics (AO) on visual acuity (VA) measured at 7 different luminances (ranging from 0.8 to 50 cd/m(2)) and two contrast polarities (black letters on white background, BoW, and white letters on black background, WoB) on 7 subjects. For the BoW condition, VA(More)