• Publications
  • Influence
Thermal-Hydraulic Analyses of Heat Transfer Fluid Requirements and Characteristics for Coupling A Hydrogen Production Plant to a High-Temperature Nuclear Reactor
The Department of Energy is investigating the use of high-temperature nuclear reactors to produce hydrogen using either thermochemical cycles or high-temperature electrolysis. Although the hydrogenExpand
  • 55
  • 5
  • PDF
Flooding in a thin rectangular slit geometry representative of ATR fuel assembly side-plate flow channels
Abstract Air-water counter-current flow limit experiments were conducted in thin rectangular channels at atmospheric pressure. The parameters were: narrow channel width, either 1.1 mm or 2.2 mm;Expand
  • 8
  • 3
Air-ingress analysis: Part 1. Theoretical approach
Abstract Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy (DOE), is performing research and development that focuses on key phenomena important during potentialExpand
  • 21
  • 3
Comprehensive thermal hydraulics research of the very high temperature gas cooled reactor
The Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy, is conducting research on the Very High Temperature Reactor (VHTR) design concept for the Next GenerationExpand
  • 7
  • 2
Modular Pebble Bed Reactor
  • 15
  • 2
Thermal Hydraulics of the Very High Temperature Gas Cooled Reactor
The U.S Department of Energy (DOE) is conducting research on the Very High Temperature Reactor (VHTR) design concept for the Next Generation Nuclear Plant (NGNP) Project. The reactor design will be aExpand
  • 10
  • 2
  • PDF
Radio frequency field intensity mapping using a composite spin-echo sequence.
A novel radio frequency (RF) field intensity mapping or imaging method using a composite NMR spin-echo sequence is proposed. A composite spin-echo RF pulse with 90 degrees y-180 degrees x-90 degreesExpand
  • 36
  • 1
An optimized multislice acquisition sequence for the inversion-recovery MR imaging.
An optimized multislice data acquisition scheme for inversion-recovery MR imaging is proposed and experimental results are presented. In this new scheme, instead of forming a set of multisliceExpand
  • 11
  • 1
Phase‐Scrambled RF Excitation for 3D Volume‐Selective Multislice NMR Imaging
An RF excitation technique with which one can improve the effective dynamic range of the receiver and reduce the interference between slices for 3D volume‐selective multislice MRI is described. TheExpand
  • 10
  • 1
Effect of Reacting Surface Density on the Overall Graphite Oxidation Rate
Graphite oxidation in an air-ingress accident is presently a very important issue for the reactor safety of the very high temperature gas cooled-reactor (VHTR), the concept of the next generationExpand
  • 3
  • 1