This paper reports on prospective tests of a system protection scheme against long-term voltage instability relying on a set of distributed controllers, each monitoring a transmission voltage, blocking tap changers and shedding loads in a zone. The emergency actions adjust in magnitude and location to the disturbance. Each controller acts in closed-loop,(More)
This papers deals with the emergency control of Load Tap Changers (LTCs) to face low transmission voltages or voltage instability situations. The proposed simple control logic consists in reverting the tap movements once the voltage at a monitored transmission bus falls below some threshold. A deadband on this voltage allows the system to settle down in(More)
An approach inspired of Model Predictive Control is proposed to determine a sequence of control actions aimed at alleviating thermal overloads in emergency conditions. The algorithm brings the line currents below their limits in the time interval left by protections, while accounting for constraints on control changes at each step. Its closed-loop nature(More)
An approach inspired by model predictive control is proposed to determine a sequence of control actions aimed at alleviating thermal overloads. The algorithm brings the line currents below their limits in the time interval left by protections while accounting for constraints on control changes at each step. Its closedloop nature allows to compensate for(More)
A new design of load shedding against long-term voltage instability is proposed. It uses a set of distributed controllers, each monitoring a transmission voltage and controlling a group of loads. Each controller acts in closed-loop, shedding amounts that vary in magnitude and time according to the evolution of its monitored voltage. The whole system(More)
A two-level adaptive load shedding scheme against voltage instability is proposed, adjusting its actions to the severity of the situation. The lower level includes a set of distributed controllers which curtail loads once the voltages at monitored transmission buses fall and stay for some time below threshold values. The adaptive nature of the proposed(More)
This paper reports on prospective tests of a system protection scheme against longterm voltage instability relying on a set of distributed controllers, each monitoring a transmission voltage, blocking tap changers and shedding loads in a zone. The emergency actions adjust in magnitude and location to the disturbance. Each controller acts in closedloop,(More)