To measure and compare the contrast to noise ratio (CNR) as a function of dose for the CBCTs produced by the mega-voltage (MV) imaging beam line (IBL) and the treatment beam line (TBL), and to compare the dose to target and various critical structures of pediatric patients for the IBL CBCT versus standard TBL orthogonal port films. Two Siemens Oncor linear(More)
Quantitative reconstruction of cone beam X-ray computed tomography (CT) datasets requires accurate modeling of scatter, beam-hardening, beam profile, and detector response. Typically, commercial imaging systems use fast empirical corrections that are designed to reduce visible artifacts due to incomplete modeling of the image formation process. In contrast,(More)
Megavoltage cone beam computed tomography (MVCBCT) is routinely used for visualizing anatomical structures and implanted fiducials for patient positioning in radiotherapy. MVCBCT using a 6 MV treatment beam with high atomic number (Z) target and flattening filter in the beamline, as done conventionally, has lower image quality than can be achieved with a MV(More)
PURPOSE To use an imaging beam line (IBL) to obtain the first megavoltage cone-beam computed tomography (MV CBCT) images of patients with a low atomic number (Z) target, and to compare these images to those taken of the same patients with the 6 MV flattened beam from the treatment beam line (TBL). METHODS The IBL, which produces a 4.2 MV unflattened beam(More)
We describe a focused beam-stop array (BSA) for the measurement of object scatter in imaging systems that utilize x-ray beams in the megavoltage (MV) energy range. The BSA consists of 64 doubly truncated tungsten cone elements of 0.5 cm maximum diameter that are arranged in a regular array on an acrylic slab. The BSA is placed in the accessory tray of a(More)
PURPOSE To quantify the improvement in megavoltage cone beam computed tomography (MVCBCT) image quality enabled by the combination of a 4.2 MV imaging beam line (IBL) with a carbon electron target and a detector system equipped with a novel sintered pixelated array (SPA) of translucent Gd(2)O(2)S ceramic scintillator. Clinical MVCBCT images are(More)
The accurate delivery of external beam radiation therapy is often facilitated through the implantation of radio-opaque fiducial markers (gold seeds). Before the delivery of each treatment fraction, seed positions can be determined via low dose volumetric imaging. By registering these seed locations with the corresponding locations in the previously acquired(More)