Learn More
The main goal of the present paper is to quantify, in homogeneous and heterogeneous phantoms, the differences between experimentally measured dose distributions inside it, and those calculated by the(More)
Monte Carlo treatment planning techniques provide a very accurate dose calculation compared to ‘conventional’ deterministic treatment planning systems. In the present work, the irradiation of the(More)