This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set(More)
Calculations of the energy response of an agar-alanine phantom dosimeter (AAPD) to electrons in the energy range of 0.15-20 MeV together with experimental results at 16 MeV are presented. It is shown that the sensitivity of the EPR dosimeter (EPR signal/Gray) is independent of alanine crystal size and varies less than 2%, in the electron energy range(More)
The effects of boric acid admixture on the intensity and line structure of EPR spectra of free radicals produced in alanine by thermal neutrons are presented. The EPR signal enhancement, up to a factor of 40 depending on the boron concentration, is related to additional energy deposition in alanine crystals by the disintegration products resulting from the(More)
In this study, we present the results of in vivo dosimetry, using electron paramagnetic resonance in l-alanine, performed on 13 patients treated for gynaecological cancers. The doses from (137)Cs (12 samples) and (192)Ir (one sample) brachytherapy sources were determined inside vagina. The detectors had a form of small cellulose capsules tightly filled with(More)
PURPOSE The objective of this study was evaluation of accuracy of in vivo dosimetry using electron paramagnetic resonance (EPR) in alanine. Additionally, we aimed to identify sources of uncertainty in dose determination and quantitative assessment of physical factors that may result in discrepancies between the measured and planned single-fraction doses. (More)
The objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 11 molars, which were cut into two halves. One half of each tooth was irradiated in a 60Co(More)
Despite the considerable improvement in accuracy in comparison with previous intercomparison programmes, the outcome of the recent 3rd International Intercomparison on EPR Tooth Dosimetry has demonstrated that performance of various protocols practised in different laboratories significantly varies. SCRM and MUG took part in this intercomparison with their(More)
Exposure of gamma-irradiated L-alanine samples to sunlight and to light from a regular, fluorescent lamp resulted in significant changes in their EPR resonance patterns, both to spectral shapes and intensities. The experimental EPR spectra were numerically decomposed into three components reflecting contributions of three different radicals (R1-R3)(More)
In this work we present a study of light-induced effects on free radicals and their transformations in gamma-irradiated pure L-alanine and in commercially available alanine detectors: rods, pellets and films. Samples irradiated to doses from 2 Gy to 4000 kGy were exposed to light from a fluorescent lamp and to ordinary daylight. The observed changes in EPR(More)
Microcrystalline samples of L-alanine irradiated with energetic high-LET cobalt and iron ions had different EPR spectra compared to alanine samples irradiated with low-LET photons. The differences in the shapes of the EPR spectra and their dependence on the microwave power are related to the differences in the microwave power saturation of the radicals(More)