• Publications
  • Influence
Dislocations after total hip arthroplasty.
  • R. Y. Woo, B. Morrey
  • Medicine
    The Journal of bone and joint surgery. American…
  • 1 December 1982
TLDR
During the ten-year period ending in 1978, 10,500 conventional total hip arthroplasties were performed at the Mayo Clinic; dislocation developed after 331 of these procedures; cross correlations of the data were performed and showed that previous surgery on the hip was the most significant of the factors predisposing to dislocation.
Results of delayed excision of the radial head after fracture.
TLDR
This study demonstrates the effectiveness of delayed excision after failure of closed management of fractures of the radial head with some justification for the initial closed treatment of these fractures.
The Elbow and Its Disorders
TLDR
Joint Replacement Arthroplasty Elbow Arthro Plasty: Historical Perspective, Current Concepts Resurfacing Elbow Replacement Ar Throplasty: Rationale, Techniques, And Results Semiconstrained Elbow replacements: Results In Rheumatoid Arthritis Total Elbows Arthro plasty For Juvenile Rheumatic Arthritis SemiconStrained Elbows Replacement: Results in Traumatic conditions.
Rupture of the distal tendon of the biceps brachii. A biomechanical study.
TLDR
It is suggested that immediate surgical reinsertion of the biceps tendon into the radial tuberosity, compared with other modes of treatment, restores more strength of flexion and supination.
Fractures of the coronoid process of the ulna.
  • W. Regan, B. Morrey
  • Medicine
    The Journal of bone and joint surgery. American…
  • 1 October 1989
TLDR
Reduction and fixation, followed by early motion when possible, may be the preferred treatment for patients who have a Type-III fracture, which correlated well with the type of fracture.
A biomechanical study of normal functional elbow motion.
TLDR
The motion needed to perform essential daily activities is obtainable with a successful total elbow arthroplasty and may be used for the determination of disability impairment, to determine the optimum position for elbow splinting or arthrodesis, and to assist in the design of elbow prostheses.
Effect of femoral head size on wear of the polyethylene acetabular component.
TLDR
The amounts of resorption of the proximal part of the femoral neck and of lysis of the distal part ofthe femur both correlated positively with the extent of linear and volumetric wear; this suggests an association between the amount of debris from wear and these changes in the Femoral Neck and proximal parts of the Femur.
...
...