B. G. Belenkii

  • Citations Per Year
Learn More
A highly sensitive method for the determination of myoglobin in serum is described, based on high-performance size-exclusion chromatography with chemiluminescence detection. Serum proteins are separated according to their molecular masses on columns packed with TSK-SW gel and those containing haem are detected selectively by post-column chemiluminescence(More)
In gel permeation chromatography on macroporous swelling sorbents, deviations from the Benoit principle of universal calibration were observed. It is suggested that these are caused by different degrees of thermodynamic compatibility of the eluted polymers with the sorbent matrix.
The application of adsorption, precipitation and extraction thin-layer chromatography to the identification of block copolymers, determination of their homogeneity (mixtures of homopolymers), and evaluation of their compositional homogeneity by one- and two-dimensional, multistage and gradient methods, is described. To detect the polymers on the thin-layer(More)
A combination of gel permeation chromatography (GPC), thin-layer chromatography (TLC) and pyrolysis gas chromatography (PGC) has been used for investigations of a polymethyl methacrylate-polystyrene-polymethyl methacrylate block copolymer. Continuous distribution of the polymer (40-mg sample) was attained according to the content of the styrene and methyl(More)
In gradient chromatography for proteins migrating along the chromatographic column, the critical distance X0 has been shown to exist at which the separation of zones is at a maximum and band spreading is at a minimum. With steep gradients and small elution velocity, the column length may be reduced to the level of membrane thickness--about one millimeter.(More)
The results of high-performance capillary electrophoresis (HPCE) studies of peptide, protein and double-stranded DNA separations on a laboratory-made HPCE system are presented. Parameters of the HPCE system are given. The new method of capillary surface modification by grafting poly(glycidyl methacrylate) is described. The problems of HPCE biopolymer(More)
The peculiarities of zone migration and band broadening in the reversed-phase gradient HPLC of proteins were investigated. In the isocratic mode a critical composition of the mobile phase was found at which all proteins regardless of their molecular mass migrate with equal velocity and have a capacity factor equal to the phase ratio (VP/V0), i.e., the same(More)