CaSO4:Dy and LiF TLDs do not exhibit photon energy dependence beyond +/-55% for photons in the energy range from 1 MeV to about 7 MeV. However, when sandwiched between metal filters or used in TLD badge holders having metal filters, the response changes for irradiation from high energy photons as compared to that from 60Co gamma rays (generally used for(More)
One of the major concerns for designing VLSI circuits has been the amount of power dissipated by these circuits. Hence, adiabatic techniques such as ECRL and PFAL for low power circuit design came into being. This paper proposes design of basic gates using these two techniques. Tanner ECAD tool is used and the circuits are implemented using the 1.25 micron(More)
The study is aimed at optimising the glow curve structure of CaSO4:Dy phosphor for dosimetric purpose and also to understand the observed changes owing to thermal treatment in the thermoluminescence (TL) sensitivity and glow curve structure. The reversible changes in the intensities of the lower temperature satellite peak and the main dosimetric glow peak(More)
A study on CaSO4:Dy TLDs was undertaken to confirm the validity of the annealing treatment (400 degrees C, 1 h) for its re-use. The temperature range of the study was from 230 degrees C to 700 degrees C. The effect of thermal treatments on the TL sensitivity and glow curve structure showed that the lattice of CaSO4:Dy is sensitive to thermal treatment in(More)
Response of thermoluminescence (TL) discs under different filter regions of a CaSO(4):Dy based TL dosemeter system was simulated to high-energy photon beams in the energy range of 1.25 MeV to 24 MV ( approximately 9 MeV). This was done using FLUKA Monte Carlo code and also experimentally verified for some energy points. Response of disc D1 under metal(More)
The study of the well separated low and high temperature glow peaks in CaSO4:Dy and CaF2:Tm was undertaken to develop comparative data on supralinearity of low and high temperature glow peaks for their use in the estimation of elapsed time of exposure and to analyse their responses to low and high-linear energy transfer (LET) radiation. In CaSO4:Dy, unlike(More)
AIM OF STUDY The photo-neutron dose equivalents of 15 MV Elekta precise accelerators were measured for different depths in phantom, for various field sizes, at different distances from the isocenter in the patient plane and for various wedged fields. MATERIALS AND METHODS Fast and thermal neutrons are measured using passive detectors such as Columbia(More)
CaSO(4):Dy, CaSO(4):(Dy, Bi) and CaSO(4):Bi phosphors were prepared through re-crystallization method. Thermoluminescence (TL) characteristics of these phosphor samples were investigated. The radiation induced radical ions formed in these phosphors were investigated using electron paramagnetic resonance (EPR) spectroscopy. The main signals observed in both(More)
A comprehensive measurement of radioactivity concentrations of the primordial radionuclides 238U, 232Th and 40K and their decay products in the soil samples collected from the sites of Indian research stations, Bharati and Maitri, at Antarctica was carried out using gamma spectrometric method. The activity concentrations in the soil samples of Bharati site(More)
In view of the introduction of International Commission on Radiation Units and Measurements operational quantities Hp(10) and Hp(0.07), defined for individual monitoring, it became necessary to develop an algorithm that gives direct response of the dosemeter in terms of the operational quantities. Hence, for this purpose and also to improve the accuracy in(More)