PURPOSE To evaluate feasibility, accuracy, and repeatability of suprathreshold Saccadic Vector Optokinetic Perimetry (SVOP) by comparison with Humphrey Field Analyzer (HFA) perimetry. METHODS The subjects included children with suspected field defects (n = 10, age 5-15 years), adults with field defects (n = 33, age 39-78 years), healthy children (n = 12,(More)
The accurate assessment of visual field function can provide valuable information on a range of visual disorders. Saccadic Vector Optokinetic Perimetry (SVOP) is a novel instrument for measuring supra-threshold visual fields in young children who are otherwise unable to perform Automated Static Perimetry (ASP). However, limitations in Liquid Crystal Display(More)
PURPOSE We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. METHODS A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields(More)
PURPOSE We evaluated threshold saccadic vector optokinetic perimetry (SVOP) and compared results to standard automated perimetry (SAP). METHODS A cross-sectional study was done including 162 subjects (103 with glaucoma and 59 healthy subjects) recruited at a university hospital. All subjects underwent SAP and threshold SVOP. SVOP uses an eye tracker to(More)
Certain imaging technologies, such as fibred optical microscopy, operate with irregularly-spaced sparse sub-samples from their field of view. In this work, we address the problem of data restoration for applications where the observed irregularly distributed samples are corrupted by additive observation noise and sparse outliers (such as broken and damaged(More)
Significance: Optical endomicroscopy (OEM) is a novel real-time imaging technology that provides endoscopic images at a microscopic level. The nature of OEM data, as acquired in clinical use, gives rise to the presence of uninformative frames (i.e., pure-noise and motion-artefacts). Uninformative frames can comprise a considerable proportion (up to >(More)
The improvement in the quality and diagnostic value of ultrasound images has been an ongoing research theme for the last three decades. Cardiac ultrasound suffers from a wide range of artifacts such as acoustic noise, shadowing, and enhancement. Most artifacts are a consequence of the interaction of the transmitted ultrasound signals with anatomic(More)
Microvasculature density (MVD) provides an established biomarker for the prognosis of numerous diseases associated with abnormal microvascular networks. The accurate, robust and timely assessment of MVD changes facilitates disease detection, treatment monitoring and patient stratification. Nevertheless, the current gold standard (PET) for MVD quantification(More)
Recent developments in optical endomicroscopy (OEM) and associated fluorescent SmartProbes present a need for sensitive imaging with high detection performance. Inter-core coupling within coherent fiber bundles is a well recognized limitation, affecting the technology's imaging capabilities. Fiber cross coupling has been studied both experimentally and(More)
INTRODUCTION Echocardiography is commonly used in clinical practice for the real-time assessment of cardiac morphology and function. Nevertheless, due to the nature of the data acquisition, cardiac ultrasound images are often corrupted by a range of acoustic artefacts, including acoustic noise, speckle and shadowing. Spatial compounding techniques have long(More)