Alejandro P Yanez

Learn More
This study examined the relation between exposure to trauma and attitudes toward existential issues. Participants were 504 undergraduate students (average age = 19.67) who answered questions on exposure to trauma, fear of death, overall distress, and meaning in life. Results indicated that those with a history of trauma exposure had higher levels of overall(More)
In this paper an experimental analysis is undertaken of the affect a new screw-to-bone fixation system has on the stiffness of fixation systems of osteoporotic fractures based on osteosynthesis plates. The proposed system, which we have named the screw locking element (SLE), is made with elements manufactured from a biocompatible polymer material known as(More)
This paper analyses the suitability of a system comprising a Dynamic Compression Plate (DCP) and Screw Locking Elements (SLEs) to allow sufficient interfragmentary motion to promote secondary bone healing in osteoporotic fractures. Four fixation systems were mounted on bone-simulating reinforced epoxy bars filled with solid rigid polyurethane foam. Group 1,(More)
Minimally invasive plate osteosynthesis (MIPO) is an effective surgical technique in the repair of humeral and tibial shaft fractures. There is some controversy as to the minimum number of screws required to ensure correct stability to promote healing, especially when dealing with low quality bones. This work compared different systems assembled on(More)
This paper analyses whether it is possible to use dynamic compression plates (DCPs) and screw locking elements (SLEs) to vary the flexibility of osteoporotic fracture fixation without compromising the strength and stability of the construct. Compression, torsion and four-point bending static strength tests were conducted. Cyclic load tests of up to 10,000(More)
The possibility of linkage was tested in 3 large kindreds with Waardenburg syndrome type I against the ABO locus. Loose linkage is probably present; the recombination fraction in males, females, and both sexes combined seems to be approximately theta' equals 0.175, theta equals 0.255, and theta', theta equals 0.20, respectively. There are still more(More)
BACKGROUND Dynamic compression plate (DCP) constructs provide inadequate fixation in cases of poor bone quality and early weight-bearing. Screw locking elements (SLE) are flat locking nuts placed at the end of the screw to prevent screw stripping from the bone, improving fixation stability. The purpose of this work was to compare biomechanical and(More)
BACKGROUND The purpose of this study was to compare the mechanical properties of an interference screw with an expansion device in anterior cruciate ligament (ACL) reconstruction. METHODS A total of 52 porcine tibia and 20 polyurethane foam blocks (0.16g/cm3) were used. Forty pullout tests were carried out to combine the two types of bones - surrogate and(More)
Electron beam melting (EBM) was used to fabricate porous titanium alloy structures. The elastic modulus of these porous structures was similar to the elastic modulus of the cancellous human bone. Two types of cellular lattice structures were manufactured and tested: gyroids and diamonds. The design of the gyroid structures was determined by the main angle(More)