We aimed to describe and evaluate an autocalibrating algorithm for determination of cardiac output (CO) based on the analysis of an arterial pressure (AP) waveform recorded using radial artery applanation tonometry (AT) in a continuous non-invasive manner. To exemplarily describe and evaluate the CO algorithm, we deliberately selected 22 intensive care unit(More)
Adequate intraoperative infusion therapy is essential for the perioperative outcome of a patient. Both hypo- and hypervolemia can lead to an increased rate of perioperative complications and to a worse outcome. Perioperative infusion therapy should therefore be needs-based. The primary objective is the maintenance of preoperative normovolemia using a(More)
The T-Line TL-200 (Tensys Medical, San Diego, CA, USA) is a non-invasive arterial blood pressure (BP) monitoring system allowing continuous “beat-to-beat” monitoring of systolic arterial pressure (SAP), mean arterial pressure (MAP), and diastolic arterial pressure (DAP). It provides a real-time BP waveform like that obtained using an arterial catheter. The(More)
PURPOSE We aimed to evaluate a dosing algorithm for continuous vancomycin administration in intensive care unit patients. MATERIALS AND METHODS This observational study was conducted in a medical intensive care unit (German university hospital; June 2012-February 2013). Following a loading dose of 20 mg per kg actual body weight, vancomycin was(More)
BACKGROUND Monitoring cardiovascular function in acutely ill patients in the emergency department (ED) is of paramount importance. Arterial pressure (AP) is usually monitored using intermittent oscillometric measurements with an upper arm cuff. The vascular unloading technique (VUT) allows continuous noninvasive AP monitoring. In this study, we compare(More)
The CNAP system allows continuous noninvasive arterial pressure measurement based on the volume clamp method using a finger cuff. We aimed to evaluate the agreement between arterial pressure measurements noninvasively obtained using the CNAP device and arterial catheter-derived arterial pressure measurements in intensive care unit patients. In 55 intensive(More)
PURPOSE We compared blood pressure (BP) measurements obtained using radial artery applanation tonometry with invasive BP measurements using a catheter placed in the abdominal aorta through the femoral artery in patients with multiple organ dysfunction syndrome (MODS). MATERIALS AND METHODS In 23 intensive care unit patients with MODS, we simultaneously(More)
PURPOSE The purpose of this study was to investigate the impact of large-volume thoracentesis (>1000 mL) on transpulmonary thermodilution (TPTD)-derived cardiopulmonary parameters with special regard to extravascular lung water index (EVLWI). MATERIALS AND METHODS Retrospective analysis of a prospectively maintained database including TPTD measurements of(More)
Hemodynamic monitoring plays a pivotal role in the treatment of patients in the cardiac intensive care unit (CICU). The innovative radial artery applanation tonometry technology allows for continuous noninvasive arterial blood pressure (AP) measurement. By closing the gap between continuous invasive AP monitoring (arterial catheter) and intermittent(More)
BACKGROUND The aim of the study was to investigate the effect of red blood cell (RBC) transfusion on hemodynamic parameters including transpulmonary thermodilution (TPTD)-derived variables. METHODS We compared hemodynamic parameters obtained before and after RBC transfusion (2 RBC units) in 34 intensive care unit (ICU) patients. RESULTS Directly after(More)