Adeel Husain

  • Citations Per Year
Learn More
In mammography, thick or dense breast regions persistently suffer from reduced contrast-to-noise ratio (CNR) because of degraded contrast from large scatter intensities and relatively high noise. Area x-ray beam equalization can improve image quality by increasing the x-ray exposure to under-penetrated regions without increasing the exposure to other breast(More)
PURPOSE Dislocation is the most frequent complication following revision total hip arthroplasty (THA). Although several risk factors for dislocation in revision THA have been described, many cannot be modified at the time of surgery. Identifying modifiable risk factors for subsequent dislocation after revision THA provides opportunity for orthopedic(More)
Nearly 20% of patients are dissatisfied following well-performed total knee arthroplasty with good functional outcomes. Surgeons must understand the drivers of dissatisfaction to minimize the number of unhappy patients following surgery. Several studies have shown that unfulfilled expectations are a principal source of patient dissatisfaction. Patients(More)
Total knee arthroplasty (TKA) is effective in managing end-stage degenerative joint disease. Achieving favorable clinical outcomes is predicated on proper implant alignment, sizing, and rotation as well as adequate soft-tissue balancing. Modern TKA implants are designed to address the fundamental needs of attaining stability in both flexion and extension(More)
Nearly 20% of patients are dissatisfied following well-performed total knee arthroplasty with good functional outcomes. Surgeons must understand the drivers of dissatisfaction to minimize the number of unhappy patients following surgery. Several studies have shown that unfulfilled expectations are a principal source of patient dissatisfaction. Patients(More)
A retrospective review of 64 patients (M 36, F 28, average age 55 years) with 29 two-part fractures and 35 three-part fractures of the proximal humerus was conducted at a Level 1 Trauma Center. All fractures were managed with the mini external fixator. Open reduction was performed in 11 cases, closed reduction in 53. The average follow-up was 21 months(More)
OBJECTIVE The aim of this study is to describe a technique for percutaneous cervical transfacet screw placement and compare this technique to the open technique with regard to the accuracy of facet capture and the potential of placing neurovascular structures at risk. METHODS Eight cadaveric cervical spines were harvested. One side of each spine was(More)
  • 1