Learn More
The SLAC Linac can deliver to End Station A (ESA) a high-energy test beam with similar beam parameters as for the International Linear Collider (ILC) for bunch charge, bunch length and bunch energy spread.[1] ESA beam tests run parasitically with PEP-II with single damped bunches at 10Hz, beam energy of 28.5 GeV and bunch charge of (1.5-2.0)·10 10(More)
We present results obtained with the T-488 experiment at SLAC Endstation A (ESA). A material model of the ILC extraction-line design was assembled and installed in ESA. The module includes materials representing the mask, beamline calorimeter, and first extraction quadrupole, encompassing a stripline interaction-point feedback system beam position monitor(More)
  • R. Edgecock, D. Kelliher, +15 authors E. Wooldridge
  • 2008
EMMA – the Electron Model of Many Applications – is to be built at the STFC Daresbury Laboratory in the UK and will be the first non-scaling FFAG ever constructed. EMMA will be used to demonstrate the principle of this type of accelerator and study its features in detail. The design of the machine and its hardware components are now far advanced and(More)
We report preliminary results of beam tests of the FONT3 Linear Collider intra-train position feedback system prototype at the Accelerator Test Facility at KEK. The feedback system incorporates a novel beam position monitor (BPM) processor with a latency below 5 nanoseconds, and a kicker driver amplifier with similar low latency. The 56 nanosecond-long(More)
  • EMMA O -SCALI, G FFAG, +23 authors C. White
  • 2015
Users may access full items free of charge; copies of full text items generally can be reproduced, displayed or performed and given to third parties in any format or medium for personal research or study, educational or not-for-profit purposes without prior permission or charge, provided: • The authors, title and full bibliographic details is credited in(More)
Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9(More)
The International Linear Collider (ILC) has a 14 mrad crossing angle in order to aid extraction of spent bunches. As a result of the bunch shape at the interaction point, this crossing angle at the collision causes a large luminosity loss which can be recovered by rotating the bunches prior to collision using a crab cavity. The ILC baseline crab cavity is a(More)
The Interaction Point (IP) feedback system is essential for maintaining the luminosity at the International Linear Collider (ILC). It is necessary to demonstrate the performance of the feedback beam position monitor (BPM) in an electron-positron pair background similar to that expected in the ILC interaction region (IR). We have simulated the ILC beam-beam(More)
Users may access full items free of charge; copies of full text items generally can be reproduced, displayed or performed and given to third parties in any format or medium for personal research or study, educational or not-for-profit purposes without prior permission or charge, provided: • The authors, title and full bibliographic details is credited in(More)
33 Today, biological objects are studied using various microscopy methods: electronic microscopy (EM), confocal microscopy (CM), and atomic force micross copy (AFM). One of the advantages of AFM is the ability to study biological objects in solution at a resoo lution comparable to that of electron microscopy. In EM and CM, there are methods based on the use(More)