This article proposes an innovative multichannel optically stimulated luminescence (OSL) dosemeter for on-line in vivo dose verification in radiation therapy. OSL fibre sensors incorporating small Al(2)O(3):C fibre crystals (TLD(500)) have been tested with an X-ray generator. A reproducible readout procedure should reduce the fading-induced uncertainty ((More)
BACKGROUND AND PURPOSE Accurate conformal radiotherapy treatment requires manual delineation of target volumes and organs at risk (OAR) that is both time-consuming and subject to large inter-user variability. One solution is atlas-based automatic segmentation (ABAS) where a priori information is used to delineate various organs of interest. The aim of the(More)
BACKGROUND AND PURPOSE Conformal radiation therapy techniques require the delineation of volumes of interest, a time-consuming and operator-dependent task. In this work, we aimed to evaluate the potential interest of an atlas-based automatic segmentation software (ABAS) of brain organs at risk (OAR), when used under our clinical conditions. MATERIALS AND(More)
Intra-subject and inter-subject nonlinear registration based on dense transformations requires the setting of many parameters, mainly for regularization. This task is a major issue, as the global quality of the registration will depend on it. Setting these parameters is, however, very hard, and they may have to be tuned for each patient when processing data(More)
These last years, the new irradiation techniques as the conformal 3D radiotherapy and the IMRT are strongly correlated with the technological developments in radiotherapy. The rigorous definition of the target volume and the organs at risk required by these irradiation techniques, imposed the development of various image guided patient positioning and(More)
PURPOSE This paper presents the development of a protocol for quality control of a megavoltage cone beam CT imaging system (MVCB) mounted on a Siemens Oncor 6MV linear accelerator. MATERIALS AND METHODS Several parameters were controlled on the MVCB system: (1) the initial geometric calibration of the system; (2) the quality of the images (geometric(More)
PURPOSE To study the dose delivered by a megavoltage cone beam computed tomography imaging system (MVCBCT) installed on a Oncor Impression linac (Siemens). MATERIALS AND METHODS The acquisition of MVCBCT images was modelled in a treatment planning system by 67 photon beams (6 MV). A study was conducted to: compare the calculated and measured dose at the(More)
The development of conformal radiotherapy techniques (CRT) and intensity modulated CRT requires an accurate delineation of target structures and organs at risk. Thus, additional information provided by anatomical and/or functional imaging modalities can be used for volume of interest determination combined with traditionally used Computed Tomography imaging(More)
A phantom study of the accuracy of CT, MR and PET image registrations with a block matching-based algorithm Étude sur fantôme de la précision d'un algorithme de recalage par blocs pour des images TDM, IRM et TEP Abstract Purpose. – The aim of the present study was to quantitatively assess the performance of a block matching-based automatic registration(More)
PURPOSE OF STUDY Monte Carlo based treatment planning system are known to be more accurate than analytical methods for performing absorbed dose estimation, particularly in and near heterogeneities. However, the required computation time can still be an issue. The present study focused on the determination of the optimum statistical uncertainty in order to(More)