A A Gamidov

  • Citations Per Year
Learn More
AIM to study the nature of intraocular lens (IOL) opacification depending on the patient's ocular status and general condition. MATERIAL AND METHODS A total of 9 patients (9 eyes) with 3-6 year history of progressive IOL opacification were enrolled. All the IOLs were acrylic (either hydrophilic--7 cases, or hydrophobic--2 cases). Two patients had their(More)
The article studies application possibilities and potency of near infrared coagulative radiation of a diode laser for correction of postoperative iris defects followed by pupillary deformities and displacement. It is found that the use of near infrared diode laser radiation at 0.810 microm enables visual improvement through pupil enlargement or its shift to(More)
AIM to perform chemical microanalysis of mineral deposits on the surface of explanted hydrophilic acrylic intraocular lenses (IOL). MATERIAL AND METHODS Two soft IOLs made of hydrophilic acryl (one, however, hydrophobic surface coated) and explanted 3 and 6 years after implantation were examined by scanning electron microscopy (EVO LS10, "Karl Zeiss",(More)
The proposed classification contains information on filmy opacities in the area of the iridolenticular diaphragm, namely: that on opacities in the posterior lenticular capsule and prelental papillary membranes. For the sake of clinical use convenience, the working classification also comprises data on the period of formation of filmy opacities, their(More)
AIM to evaluate morphological changes in the posterior lens capsule (LC) after different techniques of cataract extraction. MATERIAL AND METHODS Eight pseudophakic human autopsy eyes were divided into two groups by the technique used for cataract extraction. Group 1 included 4 eyes following extracapsular cataract extraction (ECCE) and rigid IOL(More)
The features of interaction of laser radiation with iris tissue were determined in experimental morphological study. The potential of laser irradiation with different spectral characteristics for pupil ectopia correction is estimated. The results of morphometry showed effectiveness of near-infrared diode laser radiation, that presents as an iris contraction(More)
The rate of distant damages to intraocular lens (IOL) was studied in relation to its material and manufacture procedure (punching or turning), and its posterior lens capsular position in 120 patients (125 eyes) who had undergone laser secondary cataract discussion. The resistance of lenses made from silicone, polymethylmethacrylate (PMMA), and acryl to YAG(More)